F 350 2WD Super Duty V8-6.4L DSL Turbo (2009)
Any probe entering the terminal may enlarge the contact spring opening creating an intermittent signal.
Insert the correct mating terminal (Location A) from the service kit and feel for a loose fit.
Electrical short inside the harness
1
= Solder coated wire to ground
2
= Harness protective tape
3
= Intermittent short
Solder coated wire pierced through the insulation of another circuit
4
= Grounding foil
Electrical short within the harness
Splice tape removed
1
= Intermittent short
Splice covered
2