ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Hose Clamps|Page 2644 > < Hose Clamps|Page 2642
Page 2
background image

6. Remove the oil cooler inlet and outlet hoses.

7. Remove the lower radiator hose.

Installation 

1. Follow the removal procedure in reverse order.

^

Replace the bundling strap.

Pickup Chassis

Removal 

CAUTION:  Do not mix Standard (green) Coolant with Extended Life Coolant (orange). If this contamination occurs the service change
interval on Extended Life Coolant will be reduced from 6 years/150,000 miles to 3 years/30,000 miles.
 

1. Drain the cooling system.

2. Loosen the air intake clamp and position the air cleaner cover out of the way.

3. Remove the lower radiator hose from the water inlet connection.

Hose Clamps|Page 2644 > < Hose Clamps|Page 2642