6.

Place a steel retainer on a bench with the tabs facing up. Refer to Figure 1.

7.

Place a Nomex thermal washer over the tabs so that it rests on the barb of each tab. Then, carefully press it over the barb of one of the tabs. Repeat
the procedure for each of the remaining tabs.

NOTE:

Do not bend the tabs. The inner edge of the washer may crease slightly as it passes over the barb. This is permissible provided that the crease can be
smoothed out once the washer is in place. The washer must be installed without tearing.

8.

Push the washer down onto the back face of the retainer. Be sure it is seated uniformly on the retainer. Once installed, do not use an adhesive or
other aid to hold it in place. This is neither necessary nor permissible.