4. Remove injection pressure regulator from high pressure oil pump.
5. For installation, follow removal procedures in reverse order. Tighten injection pressure regulator to 47 Nm (35 ft lb). Tighten injection control

pressure solenoid nut to 6 Nm (53 in lb)