Accumulator HVAC: Service and Repair

SUCTION ACCUMULATOR

Removal and Installation

1. Recover the refrigerant.

2. Disconnect the A/C cycling switch connector.

3. CAUTION:  To prevent damage to the fitting and the tube, use a backup wrench when loosening or tightening the fitting nut.

Disconnect the evaporator core outlet tube.
-

Discard the O-ring seal.

4. Disconnect the auxiliary fitting.

-

Discard the O-ring seal.