background image

Brake Bleeding: Service and Repair
Master Cylinder Priming - In-Vehicle or Bench

Master Cylinder Priming - In-Vehicle or Bench  

Special Tool(s)

Material

WARNING:  Brake fluid contains polyglycol ethers and polyglycols. Avoid contact with eyes. Wash hands thoroughly after handling. If
brake fluid contacts eyes, flush eyes with running water for 15 minutes. Get medical attention if irritation persists. If taken internally, drink
water and induce vomiting. Get medical attention immediately. Failure to follow these instructions may result in personal injury.
 

CAUTION:  Do not allow the brake master cylinder reservoir to run dry during the bleeding operation. Keep the brake master cylinder reservoir filled
with the specified brake fluid. Never reuse the brake fluid that has been drained from the hydraulic system.

CAUTION:  Brake fluid is harmful to painted and plastic surfaces. If brake fluid is spilled onto a painted or plastic surface, immediately wash it with
water.

NOTE:  When any part of the hydraulic system has been disconnected for repair or replacement, air can enter the system and cause spongy brake
pedal action. This requires bleeding of the hydraulic system after it has been properly connected. The hydraulic system can be bled manually or with
pressure bleeding equipment.

NOTE:  When the brake master cylinder has been replaced or the system has been emptied, or partially emptied, it should be primed to prevent air
from entering the system.

1. For in-vehicle priming, disconnect the brake lines.