ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Key Reminder Switch > < Fuel Level Sensor - Steel Fuel Tank|Page 11122
Page 2
background image

1. NOTE:  The fuel tank must be drained completely. Upon removal of the fuel pump module, the tank must be inspected for contamination.

Remove the fuel tank.

2. Clean the area around the fuel pump mounting flange.

3. Using the special tool, remove the fuel pump module lock ring.

4. CAUTION:  The fuel pump module must be handled carefully to avoid damage to the float arm.

Completely remove the fuel pump module from the fuel tank.

5. CAUTION:

-

Inspect the surfaces of the fuel pump module flange and fuel tank O-ring seal contact surfaces. Do not polish or adjust the O-ring seal
contact area of the fuel tank flange or the fuel tank. Install a new fuel pump module or fuel tank if the O-ring seal contact area is bent,
scratched or corroded.

-

Make sure to install a new fuel pump module O-ring seal and lock ring.

NOTE:  Apply clean engine oil to the O-ring seal prior to installation.

Remove and discard the fuel pump module O-ring seal.

6. To install, reverse the removal procedure.

-

Make sure the alignment arrows on the fuel pump module and the fuel tank meet before tightening the fuel pump module lock ring.

Key Reminder Switch > < Fuel Level Sensor - Steel Fuel Tank|Page 11122