ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Extension Housing Seal, A/T|Page 4837 > < Extension Housing Seal, A/T|Page 4835
Page 3
background image

7. Using the special tool, remove the manual control lever seal.

Installation 

1. NOTE:  Prior to installing the manual control lever seal, clean the bore opening with mineral spirits.

Using the special tool, install the manual control lever seal.

2. Install the manual control lever shaft assembly.

1

Install the manual control lever shaft assembly.

2

Install and seat the manual lever shaft retaining pin below the case surface.

3

NOTE:  The inner manual valve detent lever must be seated on the flats of the manual control lever shaft assembly, and the parking pawl
actuating rod must be through the guide plate.

NOTE:  The manual control valve detent lever spring must be on the inner manual valve detent lever, and the detent lever pin must align with
the manual shift valve.

Install the parking pawl actuating rod and the inner manual valve detent lever.

4

NOTE:  Use a crescent wrench on the manual control lever or the outer flats of the manual control lever shaft assembly when installing the
inner manual valve detent lever nut.

Install the inner manual valve detent lever nut.

3. Install filter and seal assembly, fluid pan and gasket. 

Extension Housing Seal, A/T|Page 4837 > < Extension Housing Seal, A/T|Page 4835