4. Loosely install the bolts, then tighten the bolts in 2 stages, in the sequence shown.

-

Stage 1: Tighten to 20 Nm (177 lb-in).

-

Stage 2: Tighten an additional 60 degrees.

5. Connect the CKP sensor electrical connector.

6. Position the starter wiring harness and transmission fluid cooler tubes support brackets and install the nut.

-

Tighten to 25 Nm (18 lb-ft).

7. Position the power steering pump assembly and install the 3 bolts.

-

Tighten to 25 Nm (18 lb-ft).

8. Connect the RH CMP sensor electrical connector.

9. Connect the LH CMP sensor electrical connector.