ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Bearing Inspection|Page 2432 > < Bearing Inspection|Page 2430
Page 1
background image

Connecting Rod Bearing: Testing and Inspection
Connecting Rod Bearing Journal Taper and Out-of-Round

Connecting Rod Bearing Journal Taper and Out-of-Round 

Inspection 

1. Mark each connecting rod and its corresponding rod cap for correct installation.
2. Using a suitable solvent, thoroughly clean the connecting rod and rod cap.
3. Use a telescoping gauge and a 50-75 mm (2-3 inch) micrometer to measure the connecting rod bearing bore.

^

Remove the connecting rod bearings from the connecting rod and the connecting rod cap. Install the connecting rod cap onto the connecting
rod and tighten the bolts in 2 stages.
-

Stage 1: Tighten to 45 Nm (33 lb-ft).

-

Stage 2: Tighten to 68 Nm (50 lb-ft).

^

Measure and record the connecting rod bearing bore as indicated. Install new connecting rods if not within specification.

4. Use a telescoping gauge and a 50-75 mm (2-3 inch) micrometer to measure the connecting rod bearing bore taper.

1

Measure the bearing bore inside diameter near the large chamfer.

2

Measure the bearing bore inside diameter near the small chamfer.
-

The difference between the 2 readings is the bore taper. Install new connecting rods if not within specifications.

Bearing Inspection|Page 2432 > < Bearing Inspection|Page 2430