Coupler HVAC: Service and Repair

SPRING LOCK COUPLING

Special Tool(s)

Special Tool(s)

Disconnect

1. Remove the spring lock coupling clip, if equipped.

2. CAUTION:  Do not use metal tools to remove the O-ring seals. They may cause axial scratches across the O-ring seal grooves, resulting in

refrigerant leaks.

Push the Refrigerant Coupling Spring Remover into the cage opening to release the female fitting from the spring lock coupling spring and pull the
fitting apart.
-

Remove the O-ring seals using a non-metallic tool.

3. CAUTION:  Do not use a screwdriver or similar tool to remove the air conditioning (A/C) tube lock coupling spring; this may cause axial

scratches across the O-ring seal grooves resulting in refrigerant leaks.

Remove the spring lock coupling spring with a small hooked wire.

Connect

1. Install the spring lock coupling spring.