Initial Inspection and Diagnostic Overview|Page 13386 > < Initial Inspection and Diagnostic Overview
Page 2
background image

Interior Lighting Delay

The interior lighting delay feature provides temporary illumination of the courtesy lamps after the doors are opened and then closed. The interior
lighting delay feature keeps the courtesy lamps on for a period of 25 seconds. If during the 25-second delay time the SJB detects that the ignition has
been turned to RUN, ACC, START, or if the vehicle is locked using the remote keyless entry (RKE) transmitter, the courtesy lamp illumination is
discontinued. If the doors are unlocked by entering in a valid code on the keypad, the SJB goes into the illuminated entry mode.

Illuminated Entry

The illuminated entry requests the courtesy lamps to illuminate when the ignition is OFF and the RKE transmitter UNLOCK button is pressed or a
valid unlock code is entered into the keypad. The illuminated entry requests the courtesy lamps off after 25 seconds have elapsed, the ignition is
rotated out of OFF, when the RKE transmitter LOCK button is pressed, or by the keypad lock code.

Illuminated Exit

The illuminated exit requests the courtesy lamps illuminate for 25 seconds when all doors are closed and the ignition key is removed from the ignition
lock cylinder. The illuminated exit deactivates when any door becomes ajar, the ignition key is inserted into the ignition lock cylinder, or 25 seconds
have elapsed.

Theater Lighting

The theater lighting option ramps-up the courtesy lamps over 0.7 second when courtesy lamp activation is requested. The theater lighting feature
ramps-down the courtesy lamps over 1.7 seconds when interior lighting deactivation is requested by any feature.

Interior Lamp Arbitrator

The interior lamp arbitrator (located in the SJB) chooses between the interior lighting, the interior mode, the interior lighting delay, the illuminated
entry, the illuminated exit, the battery saver, and the alarm flash processing to determine which feature has precedence of activating and deactivating
the interior lamps.

The features are prioritized as follows:
-

Battery saver

-

Manual interior lighting

-

Courtesy lighting

-

Courtesy lighting delay

-

Illuminated entry

-

Illuminated exit

Battery Saver

The battery saver relay is internal to the SJB and provides automatic shut-off of the demand lamps (vanity lamps, map lamps, and underhood lamp)
and courtesy lamps after a time-out period in order to save battery voltage. A timer in the SJB is started when the ignition is turned to the OFF
position. When the time-out period for the lamps has elapsed, the voltage is automatically shut off to the lamps by the battery saver. While the battery
saver has voltage disabled, if the ignition is turned to any position other than OFF, any door becomes ajar, the key is removed from the ignition, a 
dome lamp is turned on, a keypad unlock is received or the UNLOCK button of the RKE transmitter is pressed, the battery saver restores voltage and
starts the timer again.

NOTE:  Time out is 1 minute if the vehicle has less than 80 km (50 miles).

The battery saver time-outs are as follows:
-

Courtesy lamps, if the dome lamp is off = 10 minutes

-

Courtesy lamps, if the dome lamp is on, demand lamps = 10 minutes

Field-Effect Transistor (FET) Protection

The SJB utilizes a FET protective circuit strategy for many of its outputs (for example, the headlamp output circuit). Output loads (current level) are
monitored for excessive current (typically short circuits) and are shut down (turns off the voltage or ground provided by the module) when a fault is
detected. A continuous DTC is stored at that time for the fault. The circuit will then reset after a customer demand of the function (switching the
component on, battery saver being energized). When an excessive circuit load occurs several times, the module shuts down the output until a repair
procedure is carried out. At the same time, the continuous DTC that was stored on the first failure will not clear by a command to clear the continuous
DTCs. The module will not allow this code to be cleared or the circuit restored to normal until a successful on-demand self-test proves that the fault
has been repaired. After the on-demand self-test has successfully completed (no on-demand DTCs present), the continuous DTC will have been
cleared and the circuit function will return.

Each circuit has three predefined levels of short circuit tolerance established in the module based each circuits' capability. When the first or second
level is reached, the continuous DTC associated with the circuit sets along with DTC B106E. These DTCs may be cleared using the Clear DTC
operation on the scan tool as long as the fault itself has been corrected. If any of the circuits are shorted past the third level, then B106F and B1342
sets along with the associated continuous DTC. This DTC cannot be cleared and the module must be replaced.

The SJB FET protected output circuits for the interior lighting system are for the interior lamp output, cargo and running board lamp circuits.