3. Tighten the bolts in the sequence shown.
4. Position the fuel charging wiring onto the valve cover studs and connect the fuel pressure regulator vacuum hose.

5. Connect the LH ignition coil electrical connectors and the LH fuel injector electrical connectors.

6. Connect the crankcase ventilation tube to the valve cover.