Accumulator HVAC: Service and Repair

REMOVAL 

1. Disconnect the battery ground cable.
2. Recover the refrigerant.

3. Disconnect the A/C cycling switch connector.

4. Disconnect the evaporator core outlet tube.

CAUTION:  To prevent damage to the fitting and the tube, use a backup wrench when removing the suction accumulator/drier.

5. Disconnect the manifold and tube assembly.

6. Remove the suction accumulator/drier bracket clamp bolts and remove the suction accumulator/drier.