ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Hose/Line HVAC > < A/C High Pressure Safety Valve
Page 1
background image

High Pressure Safety Valve HVAC: Service and Repair
Compressor Relief Valve

REMOVAL 

1. Recover the refrigerant.

2. Remove the pressure relief valve.

INSTALLATION 

1. Follow the removal procedure in reverse order.

-

Lubricate the O-ring seal with Motorcraft YN-12c refrigerant oil F2AZ-19577-AB or equivalent meeting Ford specification WSH-M1C231-B.

Hose/Line HVAC > < A/C High Pressure Safety Valve