F 450 2WD Super Duty V8-5.4L SOHC VIN L (2003)
Service Port HVAC: Description and Operation
Service Gauge Port Valve
The high-pressure service gauge port valve is located on the A/C manifold and tube.
The low pressure service gauge port valve is located on the suction accumulator.
The fitting is an integral part of the refrigeration line or component.
^
Special couplings are required for both the high side and the low side service gauge ports.
^
The Schrader-type valve core can be replaced if the seal leaks.
^
Always install the A/C charging valve cap on the service gauge port valves after repairing the refrigerant system.