ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Air Door, HVAC > < A/C - Lack of Cooling Ability|Page 8454
Page 3
background image

7. Remove the suction accumulator screws and the suction accumulator.

-

To install, tighten to 10 Nm (89 lb-in).

8. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

9. Evacuate, leak test and charge the refrigerant system.