ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

A/C - Lack of Cooling Ability|Page 7409 > < A/C - Lack of Cooling Ability|Page 7407
Page 1
background image

Accumulator HVAC: Service and Repair

SUCTION ACCUMULATOR

REMOVAL

CAUTION:  Refrigerant Compressor Oil (mineral oil) F73Z-19577-AA (Motorcraft YN-9-A) should be used to lubricate R-134a refrigerant
system O-ring seals only and should not be added to R-134a refrigerant systems as an A/C compressor lubricant. PAG Refrigerant Compressor
Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) or equivalent meeting Ford specification WSH-M1C231-B only should be used as
an A/C compressor lubricant.

1. Recover the refrigerant.

2. Disconnect the A/C cycling switch connector.

3. CAUTION:  To prevent damage to the fitting and the tube, use a backup wrench when loosening or tightening the fitting nut.

Disconnect the evaporator core outlet tube.
-

Discard the O-ring seal.

4. Disconnect the manifold and tube assembly.

-

Discard the O-ring seal.

A/C - Lack of Cooling Ability|Page 7409 > < A/C - Lack of Cooling Ability|Page 7407