Initial Inspection and Diagnostic Overview|Page 3002 > < Initial Inspection and Diagnostic Overview|Page 3000
Page 23
background image

-

Are the resistances less than 5 ohms?

Yes

CONNECT the negative battery cable. GO to I4.

No

REPAIR the circuit in question. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
I4 CHECK FOR CORRECT DSM OPERATION

-

Disconnect all the DSM connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the DSM connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new DSM. CLEAR the DTCs. REPEAT the network test with the scan tool. TEST the system for normal operation.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------

Pinpoint Test J: The HVAC Module Does Not Respond To The Scan Tool

Communications Network

Pinpoint Tests

Pinpoint Test J: The HVAC Module Does Not Respond To The Scan Tool

Refer to Wiring Diagram Set 10, Grounds for schematic and connector information.  See: Diagrams/Electrical Diagrams/Diagrams By Number

Refer to Wiring Diagram Set 13, Power Distribution/SJB for schematic and connector information.  See: Diagrams/Electrical Diagrams/Diagrams By
Number

Refer to Wiring Diagram Set 14, Module Communications Network for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Normal Operation

The HVAC module communicates with the scan tool through the Medium Speed Controller Area Network (MS-CAN). Circuits VDB06 (GY/OG)
(MS-CAN +) and VDB07 (VT/OG) (MS-CAN -) provide the network connection to the HVAC module. Voltage to the HVAC module is provided by
circuits SBP15 (WH/RD) and CBP37 (WH). Ground is provided by circuit GD133 (BK).

The HVAC module communicates with the scan tool on the MS-CAN.

Initial Inspection and Diagnostic Overview|Page 3002 > < Initial Inspection and Diagnostic Overview|Page 3000