ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

A/C - Lack of Cooling Ability|Page 7409 > < Wheel Hubs and Bearings - Full Floating Axle - Dana|Page 7399
Page 1
background image

Accumulator HVAC: Customer Interest
A/C - Lack of Cooling Ability

TSB 08-13-5

07/07/08

LACK OF NC COOLING DUE TO DESICCANT 
MATERIAL CLOGGING THE ORIFICE TUBE

FORD:
2004-2005 Excursion
2004-2007 F-Super Duty, F-650, F-750

This article supersedes TSB 06-17-12 to update the Part List.

ISSUE
Some 2004-2007 F-Super Duty 250-750, and 2004-2005 Excursion vehicles may exhibit a lack of air conditioning (A/C) cooling, due to desiccant
material clogging the evaporator core orifice tube. Symptoms may include excessive high side pressures.

ACTION
Follow the Service Procedure steps to correct the condition.

SERVICE PROCEDURE

Inspect the orifice tube for desiccant material clogging the tube. This material has been described as being like sand, with a greenish color. If desiccant
material is present, refer to the following Service Procedure. If not, follow normal diagnostics.

NOTE

IT IS VERY IMPORTANT TO ENSURE A COMPLETE FLUSHING OF THE REFRIGERANT SYSTEM IS PERFORMED TO REMOVE ALL
CONTAMINANTS. IF NOT, A REPEAT CLOGGING CONDITION MAY OCCUR.

1.

Replace the orifice tube. Refer to Workshop Manual (WSM), Section 412-03: Removal And Installation - Evaporator Core Orifice.

2.

Replace the suction accumulator/drier with a revised part. Refer to WSM, Section 412-03: Removal And Installation - Suction Accumulator.

3.

Replace the compressor. Refer to WSM, Section 412-03: Removal And Installation - Compressor.

4.

Flush the condenser, the lines and the evaporator core. Refer to WSM, Section 412-00: General Procedures - A/C System Flushing.

5.

Recharge system.

NOTE

FOR F-SUPER DUTY 650/750 APPLICATIONS, REVIEW ENGINE APPLICATION WITH COMPRESSOR PART NUMBER. THERE ARE 3
DIFFERENT COMPRESSOR APPLICATIONS DEPENDING ON ENGINE CONFIGURATION.

Parts Block
WARRANTY STATUS: Eligible Under Provisions Of New Vehicle Limited Warranty Coverage 
IMPORTANT: Warranty coverage limits/policies are not altered by a TSB. Warranty coverage limits are determined by the identified causal part.

OPERATION

DESCRIPTION

TIME

MT081305

Claim SLTS Operation Or

Actual

Use Actual Time If SLTS

Time

Operation Is Not Available

DEALER CODING

CONDITION

A/C - Lack of Cooling Ability|Page 7409 > < Wheel Hubs and Bearings - Full Floating Axle - Dana|Page 7399