Ignition OFF.

-

Disconnect: TBC Module C2142.

-

Ignition ON.

-

Measure the voltage between ground and:
-

TBC module C2142-8, circuit SBB05 (GY/RD), harness side.

-

TBC module C2142-12, circuit CBP33 (WH/BN), harness side.

-

Are the voltages greater than 10 volts?

Yes

GO to G5.

No

VERIFY BJB fuse 5 (30A) is OK. If OK, REPAIR circuit SBB05 (GY/RD).

VERIFY SJB fuse 33 (10A) is OK. If OK, REPAIR circuit CBP33 (WH/BN).

If either fuse is not OK, REFER to the Wiring Diagrams to identify the possible causes of the circuit short.

CLEAR the DTCs. REPEAT the self-test.

-------------------------------------------------
G5 CHECK THE TBC MODULE GROUND CIRCUIT FOR AN OPEN

-

Ignition OFF.

-

Measure the resistance between TBC module C2124-11, circuit GD115 (BK/GY), harness side and ground.

-

Is the resistance less than 5 ohms?

Yes

GO to G6.

No

REPAIR circuit GD115 (BK/GY). CLEAR the DTCs. REPEAT the self-test.

-------------------------------------------------
G6 CHECK THE TBC MODULE PWM OUTPUT CIRCUIT FOR AN OPEN

-

Disconnect: Trailer Tow C4099.

-

Measure the resistance between trailer tow C4099-3, circuit CAT19 (BU), harness side and TBC module C2142-14, circuit CAT19 (BU), harness
side.

Initial Inspection and Diagnostic Overview|Page 7217 > < Initial Inspection and Diagnostic Overview|Page 7215