Outside Temperature Display: Description and Operation

Climate Control System

WARNING: Take the following precautions when repairing an air conditioning system containing R-134a:

-

Always wear safety goggles.

-

Avoid contact with liquid refrigerant R-134a. R-134a vaporizes at approximately -25°C (-13°F) under atmospheric pressure and will
freeze skin tissue.

-

Never allow refrigerant R-134a gas to escape in quantity in an occupied space. It will displace the oxygen needed to support life.

-

Never use a torch in an atmosphere containing R-134a gas. R-134a is non-toxic at all normal conditions, but it decomposes when exposed
to high temperatures such as a torch flame. During decomposition it releases irritating and toxic gasses (as described in the MSDS sheet
from the manufacturer). Decomposition products are hydrofluoric acid, carbon dioxide and water.

Failure to follow these instructions may result in serious personal injury.

WARNING: Use extreme care and observe all safety and service precautions related to the use of refrigerants as outlined on refrigerant tank
and on recovery and charging equipment. Failure to follow these instructions may result in serious personal injury.

NOTICE: To avoid damaging the vehicle or Air Conditioning (A/C) components, the following precautions must be observed.

-

The A/C refrigerant of all vehicles must be identified and analyzed prior to refrigerant charging. Failure to do so can contaminate the shop bulk
refrigerant and other vehicles.

-

Do not add R-12 refrigerant to an A/C system that requires the use of R-134a refrigerant. These 2 types of refrigerant must never be mixed. Doing
so can damage the A/C system.

-

Charge the A/C system with R-134a refrigerant gas while the engine is running only at the low-pressure side to prevent refrigerant slugging from
damaging the A/C compressor.

-

Use only R-134a refrigerant. Due to environmental concerns, when the A/C system is drained, the refrigerant must be collected using refrigerant
recovery/recycling equipment. Federal, State/Provincial and/or local laws REQUIRE that R-134a be recovered into appropriate recovery
equipment and the process be conducted by qualified technicians who have been certified by an approved organization, such as ASE or Mobile Air
Conditioning Society (MACS). Use of a recovery machine dedicated to R-134a is necessary to reduce the possibility of oil and refrigerant
incompatibility concerns. Refer to the instructions provided by the equipment manufacturer when removing refrigerant from or charging the A/C
system.

-

Refrigerant R-134a must not be mixed with air for leak testing or used with air for any other purpose above atmospheric pressure. R-134a is
combustible when mixed with high concentrations of air and higher pressures.

-

A number of manufacturers are producing refrigerant products that are described as direct substitutes for refrigerant R-134a. The use of any
unauthorized substitute refrigerant can severely damage the A/C components. If repair is required, use only new or recycled refrigerant R-134a.

NOTICE: To avoid contamination of the Air Conditioning (A/C) system, the following precautions must be observed.

-

Never open or loosen a connection before recovering the refrigerant.

-

When loosening a connection, if any residual pressure is evident, allow it to leak out before opening the fitting.

-

Evacuate a system that has been opened to install a new component or one that has discharged through leakage before charging.

-

Seal open fittings with a cap or plug immediately after disconnecting a component from the system.

-

Clean the outside of the fittings thoroughly before disconnecting a component from the system.

-

Do not remove the sealing caps from a new component until ready to install.

-

Refrigerant oil will absorb moisture from the atmosphere if left uncapped. Do not open an oil container until ready to use and install the cap
immediately after using. Store the oil in a clean, moisture-free container.

-

Install a new O-ring seal before connecting an open fitting. Coat the fitting and O-ring seal with PAG oil before connecting.

-

When installing a refrigerant line, avoid sharp bends. Position the line away from the exhaust or any sharp edges that can chafe the line.

-

Tighten threaded fittings only to specifications. The steel and aluminum fittings used in the refrigerant system will not tolerate overtightening.

-

When disconnecting a fitting, use a wrench on both halves of the fitting to prevent twisting of the refrigerant lines or tubes.

-

Do not open a refrigerant system or uncap a new component unless it is as close as possible to room temperature. This will prevent condensation
from forming inside a component that is cooler than the surrounding air.

External Temperature Display

The external temperature is displayed when the EXT button is pressed. The external temperature display will update when the vehicle has been driven
above 35 kph (22 mph) for a period of time.