Pinpoint Test F: An Individual Demand Lamp Is Inoperative

Interior Lighting

Pinpoint Tests 
Pinpoint Test F: An Individual Demand Lamp Is Inoperative

Refer to Wiring Diagram Set 89, Interior Lamps for schematic and connector information.  See: Diagrams/Electrical Diagrams/Diagrams By Number

Normal Operation

The Smart Junction Box (SJB) supplies voltage to the demand lamps on circuit CLN09 (YE/GN). The demand lamps are grounded through circuit
GD115 (BK/GY), GD122 (BK) or GD179 (BK/VT).

This pinpoint test is intended to diagnose the following:

-

Wiring, terminals, or connectors

-

Interior lamp

-

Vanity lamp (if equipped)

-

Underhood lamp (if equipped)

PINPOINT TEST F: AN INDIVIDUAL DEMAND LAMP IS INOPERATIVE

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

NOTE: Failure to disconnect the battery when instructed will result in false resistance readings.

-------------------------------------------------
F1 CHECK CIRCUIT CLN09 (YE/GN) FOR AN OPEN

-

Ignition OFF.

-

Disconnect: Suspect Demand Lamp .

-

Ignition ON.

-

Measure the voltage between the suspect demand lamp, harness side and ground as follows:

-

Is the voltage greater than 10 volts?

Yes

GO to F2.

No

REPAIR the circuit in question. TEST the system for normal operation.

-------------------------------------------------
F2 CHECK THE GROUND CIRCUIT FOR AN OPEN

-

Disconnect: Negative Battery Cable.

-

Measure the resistance between the suspect demand lamp, harness side and ground as follows:

Initial Inspection and Diagnostic Overview|Page 8605 > < Initial Inspection and Diagnostic Overview|Page 8603