ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Auxiliary Climate Control|Page 6258 > < Auxiliary Climate Control|Page 6256
Page 3
background image

1. Install the rear auxiliary evaporator inlet line and connect it to the auxiliary evaporator inlet line. 

NOTE:  Lubricate the O-ring seals with PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) or
equivalent meeting Ford specification WSH-M1C231-B.

2. Snap the rear auxiliary evaporator inlet line into the line brackets.

3. Install the front auxiliary evaporator inlet line through the wheel well and connect the evaporator inlet line. 

NOTE:  Lubricate the O-ring seals with PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) or
equivalent meeting Ford specification WSH-M1C231-B.

4. Snap the rear auxiliary evaporator inlet line into the brackets.

5. Install the brackets over the studs and loosely install the nuts.

Auxiliary Climate Control|Page 6258 > < Auxiliary Climate Control|Page 6256