ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Restraints - Control Module DTCs & Associated Fault PIDs|Page 7945 > < Restraints - Control Module DTCs & Associated Fault PIDs|Page 7943
Page 1
background image

Air Bag Control Module: Service and Repair

RESTRAINTS CONTROL MODULE (RCM)

Removal

WARNING:

-

Always wear safety glasses when repairing an air bag supplemental restraint system (SRS) vehicle and when handling an air bag module.
This will reduce the risk of injury in the event of an accidental deployment.

-

The restraints control module (RCM) orientation is critical for correct air bag supplemental restraint system (SRS) operation. If a vehicle
equipped with an SRS system has been involved in a collision in which the center tunnel area has been damaged, inspect the mounting
and bracket for deformation. If damaged, the RCM must be replaced whether or not the air bags have deployed. In addition, make sure
the area of the RCM is restored to its original condition.

-

Do not handle, move or change the original horizontal mounting position of the restraints control module (RCM) while the RCM is
connected and the ignition switch is ON. Failure to follow these instructions may result in the inadvertent deployment of the safety
canopy and risk of personal injury.

-

To reduce the risk of personal injury, do not use any memory saver devices.

CAUTION:  Electronic modules are sensitive to static electrical charges. If exposed to these charges, damage can result.

NOTE:

-

When installing a new restraints control module (RCM), always make sure the correct RCM is being installed. If an incorrect RCM is installed,
erroneous DTCs will result.

-

The air bag warning lamp illuminates when the RCM fuse is removed and the ignition switch is ON. This is normal operation and does not indicate
a supplemental restraint system (SRS) fault.

-

The SRS must be fully operational and free of faults before releasing the vehicle to the customer.

-

Repair is made by installing a new part only. If the new part does not correct the condition, install the original part and carry out the diagnostic
procedure again.

1. Depower the system.
2. Remove the center console.
3. Disconnect the small RCM electrical connector.

Restraints - Control Module DTCs & Associated Fault PIDs|Page 7945 > < Restraints - Control Module DTCs & Associated Fault PIDs|Page 7943