ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 5404 > < Diagram Information and Instructions|Page 5402
Page 2
background image

Partially mated connectors

1

 = Seal

2

 = Displaced tab

3

 = Female half

4

 = Seal

5

 = Intermittent contact

6

 = Male half

7

 = Intermittent contact

Lock may be displaced into an unlocked position; pull on the connector to verify the lock.

Deformed (enlarged) female terminals

1

 = Enlarged

2

 = Normal

Any probe entering the terminal may enlarge the contact spring opening creating an intermittent signal. Insert the correct mating terminal (Location A)