ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Fluorescent Dye Leak Detection|Page 7874 > < Fluorescent Dye Leak Detection|Page 7872
Page 4
background image

2. Fill the deluxe injector loop kit reservoir with 7 ml (0.25 oz) of fluorescent dye.
3. Install the deluxe injector loop kit between the high-pressure and low-pressure service gauge port valves.

4. CAUTION:  Make sure all tools and hoses are clear of the engine cooling fan and drive belt before starting the engine.

Start the engine.

5. Open the high-pressure service valve.

6. Open the deluxe injector loop kit valves and inject the fluorescent dye into the refrigerant system.

7. Close the high-pressure service valve to allow the pressure inside the deluxe injector loop kit to equalize with the suction side of the refrigerant

system.

Fluorescent Dye Leak Detection|Page 7874 > < Fluorescent Dye Leak Detection|Page 7872