ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Procedures|Page 5947 > < Procedures|Page 5945
Page 4
background image

-

Motorcraft Premium Automatic Transmission Fluid (XT-8-QAW)

Do not mix the fluid together, damage to internal components will result.

CVT transaxle 
1. With the vehicle in NEUTRAL, position it on a hoist. 

2. Disconnect the cooler hoses from the fluid cooler.

3. NOTE:  To prevent damage to the cooler tubes, pull them straight out of the filter housing.

Disconnect the transmission fluid cooler tubes from the transaxle.
^

To install, tighten to 10 Nm (89 inch lbs.).

4. Disconnect the wiring harness from the cooler tube

Procedures|Page 5947 > < Procedures|Page 5945