ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Procedures|Page 2133 > < Procedures|Page 2131
Page 2
background image

7. NOTICE: Do not use metal scrapers, wire brushes, power abrasive discs or other abrasive means to clean the sealing surfaces. These may

cause scratches and gouges resulting in leak paths. Use a plastic scraper to clean the sealing surfaces.

Clean the exhaust manifold mating surface of the cylinder head with metal surface prep. Follow the directions on the packaging.

Installation

1. Install 6 new LH exhaust manifold studs.

-

Tighten to 12 Nm (106 lb-in).

2. NOTICE: Failure to tighten the exhaust manifold nuts to specification a second time will cause the exhaust manifold to develop an

exhaust leak.

Using a new gasket, install the LH exhaust manifold and 6 new nuts. Tighten in 2 stages in the sequence shown:

-

Stage 1: Tighten to 20 Nm (177 lb-in).

-

Stage 2: Tighten to 25 Nm (18 lb-ft).

3. Install the LH exhaust manifold heat shield and the 3 bolts.

-

Tighten to 10 Nm (89 lb-in).

4. Install the LH HO2S.

5. Install the LH catalytic converter.

Exhaust Manifold - RH

Exhaust Manifold - RH

Procedures|Page 2133 > < Procedures|Page 2131