Intake Air Duct: Service and Repair
Air Cleaner Outlet Pipe

Air Cleaner Outlet Pipe

Removal and Installation

1. Disconnect the crankcase vent tube and vacuum tube from the Air Cleaner (ACL) outlet pipe.

2. Loosen the ACL outlet pipe-to-ACL cover clamp.

-

To install, tighten to 5 Nm (44 lb-in).

3. Loosen the ACL outlet pipe-to-Throttle Body (TB) clamp.

-

Remove the ACL outlet pipe.

-

To install, tighten to 5 Nm (44 lb-in).

4. NOTE: The ACL outlet pipe should be securely sealed to prevent unmetered air from entering the engine.

To install, reverse the removal procedure.

Main Relay (Computer/Fuel System) > < Intake Air System Components - Exploded View