14. Tighten the main control cover bolts in the sequence shown.

-

Tighten to 12 Nm (106 lb-in).

15. Position the transmission fluid cooler thermal bypass valve and transmission fluid cooler tube assembly in place and install the 2 nuts.

-

Tighten to 9 Nm (80 lb-in).

16. Connect the transaxle electrical connector and install the wiring harness fastener on the main control cover stud.