ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 7020 > < Initial Inspection and Diagnostic Overview|Page 7018
Page 3
background image

The Smart Junction Box (SJB) fuse 2 (15A) supplies voltage to both trailer tow stop/turn relays.

The trailer tow LH stop/turn relay coil receives voltage when the vehicle LH rear stoplamp is illuminated. When the trailer tow LH stop/turn relay is
energized, the voltage is routed to the trailer tow LH stop/turn relay and the trailer tow connector.

The trailer tow RH stop/turn relay coil receives voltage when the vehicle RH rear stoplamp is illuminated. When the trailer tow RH stop/turn relay is
energized, the voltage is routed to the trailer tow RH stop/turn relay and the trailer tow connector.

This pinpoint test is intended to diagnose the following:

-

Fuse

-

Wiring, terminals or connectors

-

Trailer tow connector

-

Trailer tow stop/turn relay

-

Trailer

-

SJB

 

PINPOINT TEST Z: THE TRAILER STOP/TURN LAMP IS INOPERATIVE

NOTICE:  Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

NOTE:  Before beginning diagnostics, visually inspect the trailer tow connector mounted on the bumper for signs of corrosion or damage. Repair or
install a new trailer tow connector as required.

-------------------------------------------------
Z1 DETERMINE IF BOTH TRAILER STOP/TURN LAMPS ARE INOPERATIVE

 

-

Ignition OFF.

-

Determine if both trailer stop/turn lamps are inoperative.

-

Are both trailer stop/turn lamps inoperative?

Yes

VERIFY the SJB fuse 2 (15A) is OK. If OK, GO to Z2. If not OK, REFER to the Wiring Diagrams to identify the possible causes of the circuit short.  
See: Diagrams/Electrical Diagrams/Diagrams By Number

No

GO to Z3.

-------------------------------------------------
Z2 CHECK THE TRAILER TOW STOP/TURN RELAY VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

 

-

Disconnect: Trailer Tow LH Stop/Turn Relay.

-

Disconnect: SJB C2280d.

-

Measure the resistance between the trailer tow LH stop/turn relay pin 3, circuit SBP02 (YE/RD), BJB face side and the SJB C2280d-13, circuit
SBP02 (YE/RD), harness side.

Initial Inspection and Diagnostic Overview|Page 7020 > < Initial Inspection and Diagnostic Overview|Page 7018