Flex FWD V6-3.5L (2010)
Yes
GO to Z8.
No
REPAIR circuit SBP02 (YE/RD) for an open. TEST the system for normal operation.
-------------------------------------------------
Z8 CHECK THE TRAILER TOW STOP/TURN RELAY COIL GROUND CIRCUIT FOR AN OPEN
-
Measure the voltage between the trailer tow LH stop/turn relay pin 3, circuit SBP02 (YE/RD), BJB face side and the trailer tow LH stop/turn relay
pin 2, circuit GD120 (BK/GN), BJB face side.
-
Measure the voltage between the trailer tow RH stop/turn relay pin 3, circuit SBP02 (YE/RD), BJB face side and the trailer tow RH stop/turn relay
pin 2, circuit GD120 (BK/GN), BJB face side.
-
Is the voltage greater than 10 volts?
Yes
REPAIR circuit CAT06 (YE) (LH trailer stop/turn) or circuit CAT09 (GN) (RH trailer stop/turn) for an open. TEST the system for normal operation.
No
REPAIR circuit GD120 (BK/GN) for an open. TEST the system for normal operation.
-------------------------------------------------
Z9 CHECK FOR CORRECT SJB OPERATION
-
Disconnect all the SJB connectors.
-
Check for:
-
corrosion
-
damaged pins
-
pushed-out pins
-
Connect all the SJB connectors and make sure they seat correctly.
-
Operate the system and verify the concern is still present.
-
Is the concern still present?
Yes