ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Mode Door Actuator - Defrost/Panel/Floor Door|Page 5842 > < Mode Door Actuator - Defrost/Panel/Floor Door|Page 5840
Page 4
background image

Remove Smart Junction Box (SJB) fuse 15 for at least one minute.

6. NOTE: When the ignition switch is switched to the ON position, the HVAC module will initialize and calibrate the actuators. Calibration of the

actuators will take approximately 30 seconds.

Reinstall SJB fuse 15. Turn the ignition switch to the ON position and wait 30 seconds before verifying correct LH temperature blend door
operation.

Auxiliary Mode Door Actuator

Auxiliary Mode Door Actuator

Removal and Installation

1. Remove the LH quarter trim panel.

2. Remove the 2 auxiliary mode door actuator screws.

3. Disconnect the auxiliary mode door actuator electrical connector.

4. Remove the auxiliary mode door actuator.

5. To install, reverse the removal procedure.

Auxiliary Temperature Blend Door Actuator

Auxiliary Temperature Blend Door Actuator

Mode Door Actuator - Defrost/Panel/Floor Door|Page 5842 > < Mode Door Actuator - Defrost/Panel/Floor Door|Page 5840