ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2959 > < Initial Inspection and Diagnostic Overview|Page 2957
Page 91
background image

-

Is the resistance less than 5 ohms?

Yes

GO to X17.

No

CONNECT the negative battery cable. GO to X44.

-------------------------------------------------
X17 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TOGETHER WITH THE HVAC MODULE
DISCONNECTED

 

-

Disconnect: HVAC Module C228a .

-

Measure the resistance between the DLC C251-3, circuit VDB06 (GY/OG), harness side and the DLC C251-11, circuit VDB07 (VT/OG), harness
side.

-

Is the resistance less than 5 ohms?

Yes

If the vehicle is equipped with an RETM, GO to X18.

If the vehicle is not equipped with an RETM, GO to X19.

No

CONNECT the negative battery cable. GO to X45.

-------------------------------------------------
X18 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TOGETHER WITH THE RETM DISCONNECTED

 

-

Disconnect: RETM C2949b.

-

Measure the resistance between the DLC C251-3, circuit VDB06 (GY/OG), harness side and the DLC C251-11, circuit VDB07 (VT/OG), harness
side.

-

Is the resistance less than 5 ohms?

Yes

GO to X19.

Initial Inspection and Diagnostic Overview|Page 2959 > < Initial Inspection and Diagnostic Overview|Page 2957