ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Compressor to Condenser Discharge Line|Page 1162 > < Compressor to Condenser Discharge Line|Page 1160
Page 2
background image

-

To install, tighten to 15 Nm (133 lb-in).

5. Remove the 2 Evaporative Emission (EVAP) canister purge valve heat shield pin-type retainers and remove the shield.

6. Remove the 2 EVAP canister purge valve bracket bolts.

7. Remove the Thermostatic Expansion Valve (TXV) fitting nut and disconnect the fitting.

-

Discard the gasket seals.

-

To install, tighten to 15 Nm (133 lb-in).

8. Disconnect the A/C pressure transducer electrical connector.

9. Remove the condenser-to-evaporator line bracket bolt at the RH shock tower.

-

To install, tighten to 11 Nm (97 lb-in).

10. Remove the 2 coolant reservoir bolts and position the coolant reservoir aside.

11. Detach the condenser-to-evaporator line from the inner fender and remove the line.

12. To install, reverse the removal procedure.

-

Install new gasket seals and O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

13. Evacuate, leak test and charge the refrigerant system.

Compressor to Condenser Discharge Line|Page 1162 > < Compressor to Condenser Discharge Line|Page 1160