Focus L4-2.0L (2009)
Oxygen Sensor: Service and Repair
Catalyst Monitor Sensor
Catalyst Monitor Sensor
Removal and Installation
1. With the vehicle in NEUTRAL, position it on a hoist.
2. Disconnect the electrical connector and detach the wiring retainer.
3. NOTE: If necessary, lubricate the sensor threads with penetrating and lock lubricant to assist in removal.
Using the Exhaust Gas Oxygen Sensor Socket, remove the Catalyst Monitor Sensor (CMS).
-
Calculate the correct torque wrench setting for the following torque.
-
To install, tighten to 48 Nm (35 lb-ft).
4. NOTICE: Make sure that the sensor wiring is routed away from hot surfaces and sharp edges or damage to the wiring may occur.
NOTE: Apply a light coat of anti-seize lubricant to the threads of the CMS.
NOTE: Make sure that the electrical connector locking tab is engaged.
To install, reverse the removal procedure.