ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Accumulator HVAC|Description and Operation|Page 6308 > < Wheel Fastener|Specifications
Page 1
background image

Accumulator HVAC: Description and Operation

SUCTION ACCUMULATOR

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
system contamination from a failed A/C compressor or damage to the suction accumulator.

The suction accumulator is mounted behind the RH corner of the front bumper cover, in front of the RH front wheel well. The inlet tube of the suction
accumulator is attached to the evaporator outlet line. The outlet tube attaches to the A/C manifold and tube.

After entering the inlet of the suction accumulator, heavier oil-laden refrigerant contacts an internally mounted dome (which serves as an umbrella) and
drips down onto the bottom of the canister.

-

A small diameter oil bleed hole, in the bottom of the vapor return tube, allows the accumulated heavier liquid refrigerant and oil mixture to reenter
the compressor suction line at a controlled rate.

-

As the heavier mixture passes through the small diameter liquid bleed hole, it has a second chance to vaporize and recirculate through the A/C
compressor without causing compressor damage due to slugging.

-

A fine mesh screened filter fits tightly around the bottom of the vapor return tube to filter out refrigerant system contaminant particles.

-

A desiccant bag is mounted inside the canister to absorb any moisture which may be in the refrigerant system.

Accumulator HVAC|Description and Operation|Page 6308 > < Wheel Fastener|Specifications