ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Peanut Fitting|Page 7956 > < Peanut Fitting|Page 7954
Page 1
background image

Coupler HVAC: Service and Repair

1. Fit the special tool.

-

Fit the special tool in such a way that the inner collar can be inserted into the locking spring.

NOTE:  Choose the special tool according to the line diameter.

2. Separate the refrigerant line.

-

Press the special tool into the locking spring.

-

Separate the refrigerant lines.

3. Connect the refrigerant line.

-

Check the locking spring for damage.

-

Carefully remove damaged locking springs with a thin wire, and renew them.

NOTE:  Wear lint-free gloves only to avoid getting dirt on the O-rings.

Peanut Fitting|Page 7956 > < Peanut Fitting|Page 7954