Courtesy Lamp Relay: Testing and Inspection

1. Remove the relay.
2. Using a jumper wire, connect one end to Terminal 85 of the relay. Connect the other end to ground.
3. Using a second jumper wire, connect one end to Terminal 86 of the relay.
4. Connect one lead of an ohmmeter to Terminal 30 of the relay. Connect the second lead to Terminal 87 of the relay. Note the resistance.
5. Momentarily tap the unconnected end of the Terminal 86 jumper wire to the positive battery power. An audible click sh9uld be heard and the

resistance on the ohmmeter should drop to zero.

6. If routed here from a Pinpoint Test, return to that Pinpoint Test.