Focus L4-2.0L SOHC VIN P (2000)
COMPONENT TESTING PROCEDURE (voltage applied)
Disconnect the ohmmeter; connect pins 2 and 3 to 12 V DC power and pin 1 to ground. Measure voltage between pin 5 and pin 1. If the voltage is 12
V continue with the test. If not, replace the relay. Disconnect power from pin 2 and measure voltage between pin 4 and pin 1. If the voltage is 12 V,
the relay is okay. If not, replace the relay.