ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Starter Solenoid > < Starter Relay|Locations|Page 6322
Page 2
background image

COMPONENT TESTING PROCEDURE (voltage applied)

Disconnect the ohmmeter; connect pins 30 and 85 to 12 V DC power and pin 86 to ground. Measure voltage between pin 87 and pin 86. If the voltage
is 12 V continue with the test. If not, replace the relay. Disconnect power from pin 85 and measure voltage between pin 87a and pin 86. If the voltage
is 12 V, the relay is okay. If not, replace the relay.

Relay Test

1. Remove the relay.
2. Using a jumper wire, connect one end to Terminal 85 of the relay. Connect the other end to ground.
3. Using a second jumper wire, connect one end to Terminal 86 of the relay.
4. Connect one lead of an ohmmeter to Terminal 30 of the relay. Connect the second lead to Terminal 87 of the relay. Observe the resistance.
5. Momentarily tap the unconnected end of the Terminal 86 jumper wire to the positive battery power. An audible click should be heard and the

resistance on the ohmmeter should drop to zero.

6. If reverted from a Pinpoint Test, return to the Pinpoint Test.  See: Testing and Inspection/Pinpoint Tests

Starter Solenoid > < Starter Relay|Locations|Page 6322