ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

General Procedures|Removal and Installation > < Roof Opening Panel Alignment
Roof Opening Panel - Roof Opening Panel Motor Initialization Focus 1999 (08/1998-12/2004)
General Procedures

Updating Roof Opening Panel Motor Initialization

WARNING:
WARNING:The roof opening panel anti-trap function will not operate during the updating roof opening panel motor initialization procedure. Make sure that the roof opening panel opening is free of all foreign material. Failure to follow this instruction may result in personal injury.
NOTE:
NOTE:This procedure should only be carried out when the roof opening panel motor has not been disconnected.
NOTE:
NOTE:The roof opening panel alignment must be carried out prior to carrying out roof opening panel motor initialization.
For additional information, refer to Roof Opening Panel Alignment in this section.
  1. Operate the roof opening panel control switch to the up/close position until the roof opening panel is in the fully open/vent position.
  1. Release the roof opening panel control switch.
  1. Operate the roof opening panel control switch to the up/close position and hold for 30 seconds until there is a small movement (approximately 2 mm) and the roof opening panel motor stops.
  1. Release the roof opening panel control switch.
  1. Operate the roof opening panel control switch to the up/close position again within 0.5 seconds until the roof opening panel stops (one complete cycle).

Initial Roof Opening Panel Motor Initialization

WARNING:
WARNING:The roof opening panel anti-trap function will not operate during the updating roof opening panel motor initialization procedure. Make sure that the roof opening panel opening is free of all foreign material. Failure to follow this instruction may result in personal injury.
NOTE:
NOTE:This procedure must be carried out when installing any roof opening panel motor or roof opening panel.
NOTE:
NOTE:The roof opening panel alignment must be carried out prior to carrying out roof opening panel motor initialization.
For additional information, refer to Roof Opening Panel Alignment in this section.
  1. Operate the roof opening panel control switch to the up/close position.
  1. Release the roof opening panel control switch.
  1. Operate the roof opening panel control switch to the up/close position again within 0.5 seconds until the roof opening panel stops (one complete cycle).

Erasing Roof Opening Panel Motor Initialization

NOTE:
NOTE:The erasing procedure is to be carried out only when the roof opening panel motor has been detached from the roof opening panel.
NOTE:
NOTE:This procedure must be carried out before installing a previously used roof opening panel motor.
  1. Connect the roof opening panel motor electrical connector.
  1. Operate the roof opening panel control switch to the up/close position until the roof opening panel motor stops.
  1. Release the roof opening panel control switch.
  1. Operate the roof opening panel control switch again to the up/close position and hold for 30 seconds. With the roof opening panel control switch held, the roof opening panel motor will rotate in one direction.
  1. Release the roof opening panel control switch.
  1. Operate the roof opening panel control switch to the down/open position. If the roof opening panel motor does not rotate, the erasing procedure has been carried out successfully.
  1. If the roof opening panel motor rotates (with the roof opening panel control switch in the down/open position), repeat the procedure.

General Procedures|Removal and Installation > < Roof Opening Panel Alignment