ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Low-Pressure Cutoff Switch > < Evaporator Core Orifice
Air Conditioning - Suction Accumulator Focus RS 2003 (09/2002-)
Removal and Installation

Special Tool(s)

Disconnecting Tool, Refrigerant Line 3/4" (white)

412-040 (34-002)

Removal

CAUTION:
CAUTION:Renew the suction accumulator only if moisture was able to enter the open system over an extended period (two to three hours).
  1. Evacuate the air conditioning system. For additional information, refer to Section  412-00 Climate Control System - General Information.
  1. Raise the vehicle. For additional information, refer to Section  100-02 Jacking and Lifting.

  1. CAUTION:
    CAUTION:Seal the refrigerant lines and the suction accumulator to prevent dirt ingress.
    Remove the suction accumulator.
    1. Using the special tool, disconnect the refrigerant line from the suction accumulator.
    1. Detach the refrigerant line from the suction accumulator.
    1. Remove the suction accumulator retaining bolts and nuts.

Installation

  1. NOTE:
    NOTE:Install new refrigerant line O-rings.
    NOTE:
    NOTE:Coat the refrigerant line O-rings with clean refrigerant oil prior to installation.
    Install the components in the reverse order.

Low-Pressure Cutoff Switch > < Evaporator Core Orifice