5. Fill the air conditioning system (with liquid) through the high-pressure connection.
-
Open the high-pressure side shut-off valve on the gauge set.
-
Switch the service unit to "Fill" mode and fill with the prescribed quantity of liquid refrigerant (R134a).
6. Filling the air conditioning system through the low-pressure connection.
-
Open the low-pressure side shut-off valve on the gauge set.
-
Switch the service unit to "Fill" mode and fill with gaseous refrigerant.
-
Add the remaining amount of refrigerant with the air conditioning switched on. To do so run the engine at about 1200-1500 rev/min. Set the
air conditioning system to full cooling power and fresh air mode. Set the blower to full power. Fill with the remainder of the prescribed fill
quantity.
CAUTION: Only gaseous filling of the air conditioning system is carried out through the low-pressure connection.
7. Disconnect the servicing unit.
-
Close the shut-off valve.
-
Switch off the servicing unit.
-
Separate the refrigerant hoses from the air conditioning system.
-
Screw protective caps on the fill valves.
NOTE: Do not detach the high-pressure hose when the air conditioning is switched on.