ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 8111 > < Module Controlled Functions|Page 8108
Page 1
background image

General Module: Initial Inspection and Diagnostic Overview

1. Verify the customer concern.
2. Visually inspect for obvious signs of electrical damage.

VISUAL INSPECTION CHART 

Electrical
^

Central junction box (CJB) fuse(s)

^

Wiring harness 

^

Connector(s)

^

Circuit(s)

3. If the concern remains after the inspection, connect the diagnostic tool to the Data Link Connector (DLC) located beneath the instrument panel

and select the vehicle to be tested from the diagnostic tool menu. If the diagnostic tool does not communicate with the vehicle:
^

check that the program card is correctly installed.

^

check the connections to the vehicle.

^

check the ignition switch position.

4. If the diagnostic tool still does not communicate with the vehicle, refer to the diagnostic tool operating manual.
5. Carry out the DATA LINK DIAGNOSTICS test. If the diagnostic tool responds with:

^

CKT914, CKT915 or CKT70 = ALL ECUS NO RESP/NOT EQUIP, REFER to Module Communications Network (Information Bus).

^

NO RESPONSE/NOT EQUIP for GEM, GO to Pinpoint Test A.  

^

SYSTEM PASSED, retrieve and record the continuous Diagnostic Trouble Codes (DTCs), erase the continuous DTCs and carry out self- test
diagnostics for the GEM.

6. If the DTCs retrieved are related to the concern, go to the Diagnostic Trouble Code (DTC) Index.  See: Diagnostic Trouble Code Tests and

Associated Procedures

7. If no DTCs related to the concern are retrieved, refer to the appropriate vehicle system to continue diagnostics.

Initial Inspection and Diagnostic Overview|Page 8111 > < Module Controlled Functions|Page 8108