ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Fluorescent Dye Leak Detection|Page 7465 > < Fluorescent Dye Leak Detection
Page 2
background image

Special Tool(s), Part 2

SPECIAL TOOL(S)

Fluorescent Dye Detection

NOTE:  Ford Motor Company vehicles are produced with R-134a fluorescent dye installed in the refrigerant system from the factory. The location of
leaks can be pinpointed by the bright yellow-green glow of the fluorescent dye under a UV lamp. Since more than one leak can exist, make sure to
inspect each component, line, and fitting in the refrigerant system for a leak.

1. Check for leaks using a Rotunda approved UV lamp.

-

Inspect all components, lines, and fittings of the refrigerant system.

2. If a leak is found, recover the refrigerant.
3. Repair the refrigerant system leak(s).
4. Evacuate and charge the refrigerant system.
5. After the leak(s) is/are repaired, remove any traces of fluorescent dye with a general purpose oil solvent.

6. Verify the repair by running the vehicle for a short period of time and rechecking the area of the leak with a Rotunda approved UV lamp.

Fluorescent Dye Injection - Using an A/C Refrigerant Center and Dye Injector

NOTE:

-

Fluorescent refrigerant system dye is added to the refrigerant system at the factory to assist in refrigerant system leak diagnosis using a Rotunda

Fluorescent Dye Leak Detection|Page 7465 > < Fluorescent Dye Leak Detection