ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3135 > < Initial Inspection and Diagnostic Overview|Page 3133
Page 88
background image

NOTE: When re-running the network test, the network test application must be first closed or the screen display will revert back to the prior run network
test results.

-

Disconnect: SJB Fuse 25 (7.5A).

-

Enter the following diagnostic mode on the scan tool: Network Test.

-

Repeat the network test.

-

Do all other modules pass the network test?

Yes

INSTALL the removed fuse. Go To Pinpoint Test D.  See: Pinpoint Test D: The Restraints Control Module (RCM) Does Not Respond to the Scan Tool

No

INSTALL the removed fuse. GO to U14.

-------------------------------------------------
U14 CHECK FOR RESTORED NETWORK COMMUNICATION WITH THE OCCUPANT CLASSIFICATION SYSTEM MODULE
(OCSM) DISABLED

NOTE: When re-running the network test, the network test application must be first closed or the screen display will revert back to the prior run network
test results.

-

Disconnect: SJB Fuse 24 (7.5A).

-

Enter the following diagnostic mode on the scan tool: Network Test.

-

Repeat the network test.

-

Do all other modules pass the network test?

Yes

INSTALL the removed fuse. Go To Pinpoint Test F.  See: Pinpoint Test F: The Occupant Classification System Module (OCSM) Does Not Respond to
the Scan Tool

No

INSTALL the removed fuse. An intermittent fault is not present. Go To Pinpoint Test S.  See: Pinpoint Test S: Intermittent No Medium Speed
Controller Area Network (MS-CAN) Communication, One Or More Modules Are Not Respo

-------------------------------------------------

Pinpoint Test V: No Power to the Scan Tool

Communications Network

Pinpoint Tests

Pinpoint Test V: No Power To The Scan Tool

Refer to Wiring Diagram Set 14, Module Communications Network for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Normal Operation

The scan tool is connected to the Data Link Connector (DLC) to communicate with the High Speed Controller Area Network (HS-CAN) and the
Medium Speed Controller Area Network (MS-CAN) communications network. Voltage for the scan tool is provided by circuit SBP11 (BU/RD). Ground
is provided by both circuits GD116 (BK/VT).

This pinpoint test is intended to diagnose the following:

-

Fuse

-

Wiring, terminals or connectors

-

Scan tool

PINPOINT TEST V: NO POWER TO THE SCAN TOOL

Initial Inspection and Diagnostic Overview|Page 3135 > < Initial Inspection and Diagnostic Overview|Page 3133