ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Housing Assembly HVAC > < Compressor Manifold and Tube Assembly|Page 5909
Page 2
background image

4. Detach the wire harness clip from the TXV manifold and tube assembly.

5. Remove the condenser-to-evaporator line fitting nut and disconnect the fitting.

-

Discard the gasket seal.

-

To install, tighten to 15 Nm (133 lb-in).

6. Remove the compressor manifold and tube suction fitting nut and disconnect the fitting.

-

Discard the gasket seal.

-

To install, tighten to 15 Nm (133 lb-in).

7. Disconnect the A/C pressure transducer electrical connector and detach the wire harness from the TXV manifold and tube.

8. Remove the TXV fitting nut and disconnect the fitting.

-

Discard the gasket seals.

-

To install, tighten to 15 Nm (133 lb-in).

9. Remove the TXV manifold and tube assembly.

10. To install, reverse the removal procedure.

-

Install new gasket seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

11. Evacuate, leak test and charge the refrigerant system.

Housing Assembly HVAC > < Compressor Manifold and Tube Assembly|Page 5909