Removal and Installation
Remove

1. Disconnect the battery negative lead.

CAUTION:

When disconnecting multiplugs do not pull on the wiring; pull on the multiplug body.

2. Disconnect the EVAP canister purge valve multiplug.

3. Unscrew the EVAP canister purge valve retaining bolts.

4. Disconnect the vacuum hose.

5. Disconnect the vapour pipes and remove the EVAP canister purge valve.
Install
6. Refit the components in reverse order.